DIN 73378
Operative pressure for Ø 4 x 0,85 and 23°C: approx. 1044 PSI / 7 MPA / 72 bar
Operative pressure for Ø 6 x 1,25 and 23°C: approx. 1015 PSI / 7 MPA / 70 bar
Operative pressure for Ø 6 x 1,5 and 23°C: approx. 1291 PSI / 9 MPA / 89 bar
Item No. | Color | Material | Dimension | Grease | D | D1 | S | m / coil | Box | Palett |
---|---|---|---|---|---|---|---|---|---|---|
100-010 | black | PA 12 HL | 4 x 0,85 | unfilled | 4 | 2,3 | 0,85 | 50 | 1500 | 5000 |
100-010-T | transparent | PA 12 HL | 4 x 0,85 | unfilled | 4 | 2,3 | 0,85 | 50 | 1500 | 5000 |
4511-100 | black | PA 12 HL | 4 x 0,85 | NLGI class 000 | 4 | 2,3 | 0,85 | 50 | 1500 | 5000 |
100-009-25 | black | PA 12 HL | 6 x 1,5 | NLGI class 2 | 6 | 3,0 | 1,5 | 25 | 750 | 4000 |
100-004 | black | PA 12 HL | 6 x 1,5 | NLGI class 000 | 6 | 3,0 | 1,5 | 100 | 500 | 4000 |
100-003-25 | black | PA 12 HL | 6 x 1,5 | unfilled | 6 | 3,0 | 1,5 | 25 | 750 | 4000 |
100-003 | black | PA 12 HL | 6 x 1,5 | unfilled | 6 | 3,0 | 1,5 | 100 | 500 | 4000 |
4510-001 | transparent | PA 12 HL | 6 x 1,25 | unfilled | 6 | 3,5 | 1,25 | 100 | 500 | 4000 |
_____________________________________________________________________________________________________
DIN 73378
Operating pressure:
100-005 / 100-006 approx. 39 bar / 570 PSI / 4 MPA
100-006-T approx. 36 bar / 522 PSI / 3,6 MPA
100-007 approx. 44 bar / 640 PSI / 4,4 MPA
Item No. | Color | Material | Dimension | Grease | D | D1 | S | m / coil | Box | Palett |
---|---|---|---|---|---|---|---|---|---|---|
100-005 | black | PA 12 PHL | 4 x 0,85 | NLGI class 000 | 4 | 2,3 | 0,85 | 50 | 1500 | 5000 |
100-006 | black | PA 12 PHL | 4 x 0,85 | unfilled | 4 | 2,3 | 0,85 | 50 | 1500 | 5000 |
100-006-T | transparent | PA 12 PHL | 4 x 0,85 | unfilled | 4 | 2,3 | 0,85 | 50 | 1500 | 5000 |
100-007 | black | PA 12 PHL | 6 x 1,5 | unfilled | 6 | 3,0 | 1,5 | 100 | 500 | 4000 |
4513-100 | black | PA 12 PHL | 6 x 1,5 | NGLI 000 | 6 | 3,0 | 1,5 | 100 | 500 | 4000 |
_____________________________________________________________________________________________________
DIN 73378
Operating pressure:
4512-001 / 4513-101 approx. 60 bar / 870 PSI / 6 MPA
Item No. | Color | Material | Dimension | Grease | D | D1 | S | m / coil | Box | Palett |
---|---|---|---|---|---|---|---|---|---|---|
4512-001 | black | PA 12 PHLY | 6 x 1,5 | unfilled | 6 | 3,0 | 1,5 | 100 | 500 | 4000 |
4513-101 | black | PA 12 PHLY | 6 x 1,5 | NGLI 000 | 6 | 3,0 | 1,5 | 100 | 500 | 4000 |
Our plastic tubes /
tube lines are used in lubrication systems to connect the progressive
distribution unit with the lubrication point or the relubrication distributor
(or piston distributor) to the lubrication point.
Mounting advise:
Please do always use reinforcing sockets for plastic tubes with diameter 4x 0,85 and 6x1,25
Technical informations:
Material:
Plastic tube, semi-flexible: PA 12 HL
Plastic tube, flexible: PA 12 PHL
Plastic tube, (semi-)flexible: PA 12 PHLY
Standard: DIN 73378
Material properties:
All types of plastic tubes (PA 12 HL, PA 12 PHL, PA 12 PHLY) are free of plasticisers, and resistant to light or heat-induced ageing.
Permissible media:
Excellent resistance to oil, grease and lubricants, and to all types of fuels and chlorine-free cleaning agents and solvents.
Application for other media than those stated above, only upon request!
Permissible operating temperature: ca. – 60 °C to + 80 °C
The permissible operating pressures according to DIN 73378 are
calculated by means of the following formula
P = 20 · σV · s (Nenn)
-----------------------
dm
s = nominal wall thickness [mm];
dm = da – s;
σV = reference stress N/mm2 at 23 °C
Important advice for
assembly!
Our PA12HL plastic tubes according to DIN 73378 in the dimension 6x1.5 (i.e. 6 mm outer diameter and 1.5 mm wall thickness = 3 mm inner diameter) are also referred to as poly tube 6x3. For these tubes, use of a push-in socket is not required. Assembly together with a cutting ring fitting, equal to use of our push-in fitting, is easy and straight forward.
In contrast to that, push-in sockets or
reinforcement sockets must be used for PA 12 PHL polyamide tubes with wall
thickness of 0.85 mm.
Please note that push-in sockets that are "lost" or "forgotten" during assembly, may result in severe problems and major damage.
As a general rule, we recommend using push-in sockets if the wall thickness of a plastic tube is </= 1.25 mm.
In our capacity as manufacturer, we would like to make our customers aware that assembly of our components for central lubrication (tubes, hoses, screw fittings, ...) must only be performed by appropriately trained and qualified personnel.
In borderline cases, it is advisable to consult us beforehand. Have the tubes mounted only by qualified and/or accordingly trained personnel.
The warranty claims are limited to the specification of this technical data sheet.
Further warranties will not be accepted.
Download |
|
technical data sheet plastic tube 100-003 / 100-003-25 unfilled | |
Product - information grease NLGI 000 | |
Product - information grease NLGI 2 | |
Safety data sheet for grease NLGI 000 | |
Safety data sheet for grease NLGI 2 |